Model
|
Max. Power (kW)
|
Power consumption (Amps)
|
Heated air flow (m3/hr)
|
ΔT (°C)
|
BX 31
|
3
|
8,9/13,2 - 230V
|
220
|
38
|
B X 92
|
9
|
6,8/13,3 - 400V
|
900
|
36/28
|
B X 153
|
15
|
11,1/21,9 - 400V
|
1000
|
42
|
VTB 30001
|
3
|
13,0 - 230V
|
225
|
60
|
VTB 90002
|
9
|
11,5/13,0 - 400V
|
550
|
100
|
VTB 150003
|
15
|
8,0/14,0/23,0 - 400V
|
1000
|
38/60/100
|
VTB 18000
|
18
|
14,0/26,0 – 400 V
|
1000
|
70/110
|
1 cable, plug, 230V
2 cable, plug, 400V, 16A
3 cable, plug, 400V, 32A
- Good heat distribution;
- Easy access for cleaning;
- Combined frame suitable for suspension as well as carrying;
- Stackable;
- Comfortable heat;
- Suitable for closed areas;
- Can be used instantly where power is available;
- Easy to install.
- Agriculture - Drying of agricultural products.
- Horticulture - Heating of sorting areas and greenhouses.
- Industry - Heating of offi ces, canteens, stores, warehouses etc.
- Livestock - Heating of poultry houses.
- Building industry - Heating and drying out rooms, often in conjunction with a dehumidifier.
- Room thermostat - RT1, RT2, RT4;
- Hoses for recirculation;
- Connecting parts;
- Head distribution for 2 pipes;
- Head distribution for 4 pipes;
- PVC coated in polyamide;
- Rubber clips;
- Recirculation fans;
- Y and T pieces;
- Reduction pieces;
- Flanges for recirculation.